Lesson 6 of 10 · 15 min

Analysing chromatograms with RFR_F values

Calculate RFR_F values from a paper or TLC chromatogram, identify the components of a mixture by comparison with standards, and judge whether a substance is pure.

What you will be able to do

  • Calculate an RFR_F value from measured distances, both from the baseline.
  • Identify the components of a mixture by matching spots and RFR_F values with standards run under the same conditions.
  • Use the number of spots to judge the purity of a sample, and explain the limits of that judgement.

A chromatogram is evidence, and you read it with a ruler. How far a component travels depends on how far the solvent went, so the distance alone means little. Divide it by the distance the solvent front travelled and you get a number that stays the same every time the experiment is repeated under the same conditions: the retention factor.

Retention factor (both distances measured from the baseline)
RF=distance moved by the componentdistance moved by the solvent frontR_F = \frac{\text{distance moved by the component}}{\text{distance moved by the solvent front}}

Measure from the baseline to the centre of each spot, and from the baseline to the solvent front.

For the yellow spot, RF=2.08.0=0.25R_F = \dfrac{2.0}{8.0} = 0.25; for the blue spot, RF=5.68.0=0.70R_F = \dfrac{5.6}{8.0} = 0.70. Because a component can never move further than the solvent, RFR_F is always between 0 and 1, and it has no unit.

On a TLC plate the solvent front is 6.4 cm from the baseline and a spot's centre is 4.0 cm from the baseline. Calculate the spot's RFR_F value to two significant figures.

Give 2 significant figures.

Key idea

Identity and purity

  • Identity: a component of the mixture is probably the same substance as a standard if it gives a spot with the same RFR_F (and colour) under the same conditions: the same stationary phase, solvent and temperature. Running the standards on the same plate, side by side, guarantees that.
  • Composition: the number of separate spots shows the minimum number of components in the mixture.
  • Purity: a pure substance gives one spot. More than one spot means the sample is impure. One spot is good evidence of purity, but not proof: two substances with the same RFR_F in that solvent would give a single spot, so chemists repeat the test in a second solvent.

Worked example

Identifying the dyes in a food colouring from RFR_F values

  • Simple familiar

A green food colouring G was run beside three standard dyes, P (yellow), Q (blue) and R (red), on chromatography paper. The solvent front moved 10.0 cm from the baseline. The distances of the spots from the baseline were:

SampleSpot distances (cm)
G3.5 (blue), 7.8 (yellow)
P7.8
Q3.5
R5.2

Calculate the RFR_F value of each spot, identify the dyes in G, and state whether G is a pure substance.

The developed chromatogram. The solvent front is 10.0 cm above the baseline.

4 steps

Try it yourself first, then check the working one step at a time.

Method

  1. RFR_F = distance of spot ÷ distance of solvent front, both from the baseline.

  2. Match each spot of the unknown to a standard with the same RFR_F and colour.

  3. More than one spot means a mixture.

Watch out for

  • Dividing by the length of the paper instead of the distance to the solvent front.

  • Giving RFR_F a unit (it has none).

Interactive

Measure the spots

The mixture runs beside each of its dyes as a standard. Select a spot to measure it, and check that the matching spots line up across the paper.

A mixture M was run beside four standards A, B, C and D on the same paper with the same solvent. Which standards does M contain?

Solvent front 8.0 cm above the baseline.

Select all that apply.

Precision. Measure to the centre of each spot (spots spread as they travel), to the nearest millimetre. With distances of a few centimetres that limits RFR_F to two significant figures. Small spots, a long run and a flat, evenly cut paper all improve the measurement.

Worked example

Matching the ink on a forged note

  • Complex unfamiliar

Ink from a forged note (N) and from pens belonging to three suspects (X, Y and Z) were run side by side on one sheet of chromatography paper in the same solvent. The solvent front moved 9.0 cm.

SampleSpot distances from the baseline (cm)
Note N1.8, 4.5, 7.2
Pen X1.8, 7.2
Pen Y1.8, 4.5, 7.2
Pen Z4.5, 6.3

(a) Calculate the RFR_F value of each spot in the note's ink.

(b) Which pen's ink is consistent with the note? Justify your answer.

(c) A detective says the chromatogram proves suspect Y wrote the note. Evaluate this claim, and suggest how the evidence could be strengthened.

4 steps

Try it yourself first, then check the working one step at a time.

Method

  1. Calculate every RFR_F value.

  2. A match needs every component to agree, with nothing extra.

  3. When evaluating a claim, separate "consistent with" from "proves", and suggest specific further tests.

Watch out for

  • Choosing pen X because two of its spots match. A match needs all the components.

  • Accepting the detective's claim. Chromatography shows the ink could be the same, not who used it.

A student runs a sample of a newly made compound on a TLC plate and sees a single spot. Which conclusion is best supported?

Choose one answer

Common mistake

Measuring from the wrong place

Measure both distances from the baseline, not the bottom edge of the paper, and use the solvent front, not the top of the paper. An RFR_F greater than 1 means you have divided the wrong way round.

Exam tip

Reading a chromatogram in the exam

Show each RFR_F calculation with the distances, give RFR_F to two significant figures with no unit, then make the comparison explicit: "the spot at RF=0.65R_F = 0.65 matches standard C (RF=0.65R_F = 0.65), so the mixture contains C". When a question asks you to evaluate a conclusion, say what the evidence supports and what would make it stronger.

Summary

  • RFR_F = distance moved by the component ÷ distance moved by the solvent front, both from the baseline. It lies between 0 and 1 and has no unit.

  • RFR_F depends on the stationary phase, the solvent and the temperature, so compare unknowns with standards run under the same conditions, ideally on the same plate.

  • The number of spots shows the minimum number of components; matching RFR_F values identify them.

  • A pure substance gives one spot; one spot suggests, but does not prove, purity.

Finished the lesson?

Try the 3 quick checks above and the lesson completes itself, or mark it complete now.

Lesson 6 of 100% read

Save your progress with a free account