Lesson 7 of 12 · 17 min
Standard electrode potentials and E°cell
Describe the standard hydrogen electrode and what a standard electrode potential means, calculate from the data book, and state the limits of what values predict.
What you will be able to do
- Describe the standard hydrogen electrode and the standard conditions.
- Explain the term standard electrode (reduction) potential, .
- Calculate .
- Identify the limitations of values.
A zinc–copper cell gives about ; a magnesium–copper cell gives more than twice that. The voltage depends on how strongly each half-cell pulls on electrons. But a voltmeter only measures a difference between two electrodes, so you can never measure one half-cell on its own. Chemists solved this by choosing one half-cell as a reference and measuring every other half-cell against it.
Definition
The standard hydrogen electrode
The standard hydrogen electrode (SHE) is the reference half-cell. Hydrogen gas at bubbles over a platinum electrode (coated with finely divided platinum) dipping into a solution with , at . Its half-reaction, , is assigned a potential of exactly .
With zinc, the voltmeter reads and zinc is the anode. Try copper: which way do the electrons go now?
Definition
Standard electrode (reduction) potential
The standard electrode potential, , of a half-cell is the potential difference it produces when connected to the standard hydrogen electrode under standard conditions: , for gases and for every dissolved species. It is always quoted for the half-equation written as a reduction.
A positive means the oxidised form gains electrons more readily than does. A negative means it gains electrons less readily, so its reduced form gives electrons away more readily than does.
The data book lists the half-equations from the most negative at the top (, ) to the most positive at the bottom (, ). In any cell, the half-cell with the higher (more positive) is the cathode, where reduction happens. The other one runs in reverse, as an oxidation, at the anode.
Key idea
Cell potential
Use both values exactly as printed: they are both reduction potentials. A positive means the cell reaction is spontaneous.
Worked example
E°cell for a nickel–silver cell
Calculate for a galvanic cell made from a half-cell and an half-cell, and write the overall cell reaction.
Step 1: Look up E° values
; .
Step 2: Decide which is reduced
Silver has the higher , so is reduced (cathode) and Ni is oxidised (anode).
Step 3: Substitute
Both values go in as printed. Subtracting a negative number adds it.
Step 4: Overall reaction
Multiply by 2 to match nickel's two electrons: . is not doubled.
Try it yourself first, then check the working one step at a time.
Answer
; .
Method
Find both values in the data book.
The higher one is the reduction.
, values as printed.
Watch out for
Calculating by dropping nickel's negative sign.
Doubling silver's to because of the 2 in the equation.
Calculate for a galvanic cell made from a half-cell and a half-cell, using the data book.
Common mistake
Two ways to get E°cell wrong
- Flipping the sign twice. Some textbooks reverse the oxidation half-cell's sign and add. That is fine, but doing both, reversing the sign and then subtracting, gives the wrong answer. With the QCAA formula, never change a sign.
- Multiplying by coefficients. is a property of the half-cell, not of the amount of substance. When you multiply by 2 to balance electrons, its stays .
For the cell reaction , what is ?
Limitations of values. Standard electrode potentials are powerful, but they only tell you so much.
| Limitation | What it means |
|---|---|
| Standard conditions only | They apply at 298 K, 100 kPa and . Real cells run at other concentrations and temperatures, and the concentrations change as the cell runs, so the voltage changes too. |
| No information on rate | A positive says a reaction can happen, not how fast. Some predicted reactions are too slow to see, or are blocked, like aluminium behind its oxide layer. |
| Aqueous solutions only | The values are for ions in water. They don't apply to molten salts or other solvents. |
| Measured voltage is lower | Internal resistance of the cell and the salt bridge, and dirty or oxidised electrodes, make a real cell's voltage smaller than . |
| No account of overpotential | Some reactions, especially those that make gases such as , need a larger voltage than predicts. This matters in electrolysis. |
Select all the statements that are limitations of using standard electrode potentials to make predictions.
Exam tip
Write the substitution
Show your working as , with each value's sign in brackets. Give the sign of and its unit, and say what a positive value means if the question asks about spontaneity.
Summary
The standard hydrogen electrode ( at 100 kPa over Pt in , 298 K) is assigned .
is a half-cell's potential against the SHE under standard conditions, written for reduction.
The half-cell with the higher is the cathode. , using both values as printed.
Never multiply by coefficients, and never flip a sign before subtracting.
values apply only to standard conditions in water, say nothing about rate, and ignore internal resistance and overpotential.
Finished the lesson?
Try the 3 quick checks above and the lesson completes itself, or mark it complete now.