Lesson 13 of 14 · 18 min

Chromatography and electrophoresis of amino acids

Explain how paper and thin-layer chromatography and electrophoresis separate amino acids, calculate RFR_F values, and identify amino acids from chromatograms and electrophoresis results.

What you will be able to do

  • Explain separation in paper and thin-layer chromatography in terms of attraction to the stationary phase and solubility in the mobile phase.
  • Calculate RFR_F values and use them to identify amino acids.
  • Predict the direction an amino acid moves in electrophoresis from the buffer pH and its isoelectric point.
  • Analyse chromatograms and electrophoresis results, including the reliability of the method.

A protein is broken down into its amino acids by boiling it in acid. The result is a colourless solution of up to twenty very similar molecules. Which ones are there? Two techniques answer that: chromatography, which separates amino acids by how polar they are, and electrophoresis, which separates them by their charge.

Key idea

How chromatography separates

Every chromatography has a stationary phase that stays put and a mobile phase that flows past it.

  • In paper chromatography the stationary phase is the water held on polar cellulose fibres; in thin-layer (TLC) it is a thin coat of polar silica or alumina on a plate.
  • The mobile phase is a solvent, such as a mixture of butan-1-ol, ethanoic acid and water.

Each amino acid is constantly adsorbing onto the stationary phase and dissolving back into the solvent. One that is more strongly attracted to the polar stationary phase (more polar side chain, more hydrogen bonding) spends more time stuck and moves less. One that is more soluble in the mobile phase spends more time moving and travels further.

Running a chromatogram

  1. Draw a pencil baseline

    Pencil (graphite) does not dissolve and run; ink would.

  2. Spot the samples

    Small, concentrated spots of the unknown and of known amino acids (standards) side by side on the baseline.

  3. Develop

    Stand the paper in solvent below the baseline (so the spots do not dissolve into the pool), with a lid to saturate the air. Remove it before the solvent reaches the top and mark the solvent front.

  4. Make the spots visible

    Amino acids are colourless. Spray with ninhydrin and warm: they show as purple spots.

  5. Measure and calculate

    Measure from the baseline to the centre of each spot and to the solvent front.

From the data book. Both distances are measured from the baseline.
RF=distance moved by amino aciddistance moved by solventR_F = \frac{\text{distance moved by amino acid}}{\text{distance moved by solvent}}

A chromatogram of unknown X beside three standard amino acids, A, B and C.

Worked example

Identify amino acids from a chromatogram

  • Simple familiar
  • Technology active

In the chromatogram in the lesson, the solvent front is 8.0 cm8.0\unit{cm} above the baseline. Unknown X gives spots at 2.1 cm2.1\unit{cm} and 4.8 cm4.8\unit{cm}; standards A, B and C give single spots at 2.12.1, 3.43.4 and 4.8 cm4.8\unit{cm}. Calculate each RFR_F and identify the components of X.

3 steps

Try it yourself first, then check the working one step at a time.

Method

  1. Measure from the baseline to the spot centre and to the solvent front.

  2. RFR_F = spot distance ÷ solvent distance.

  3. Match to standards run under identical conditions.

Watch out for

  • Measuring from the bottom edge of the paper instead of the baseline.

  • Concluding that X contains B because B's spot lies between X's two spots.

On a paper chromatogram the solvent front is 9.6 cm9.6\unit{cm} from the baseline and an amino acid spot is 3.9 cm3.9\unit{cm} from the baseline. Calculate its RFR_F, to two significant figures.

Give 2 significant figures.

Common mistake

R_F slips

RFR_F is between 0 and 1 and has no unit. Measure both distances from the baseline, not from the bottom of the paper, and to the centre of the spot. RFR_F values depend on the solvent and the stationary phase, so compare an unknown only with standards run on the same plate in the same solvent.

Interactive

Paper chromatography of amino acids

Develop the plate, measure the RFR_F of each spot in the mixture and match it to a standard. Then try a pen baseline, or a solvent level above the baseline, to see what goes wrong.

Electrophoresis. Amino acids carry different charges at a given pH (last lesson), so an electric field can pull them apart. A strip of paper or gel is soaked in a buffer that holds the pH fixed, the mixture is spotted in the middle, and a voltage is applied across the strip.

Key idea

Which way does it move?

Compare the buffer pH with each amino acid's isoelectric point (data book):

  • pH below pI: the amino acid is a cation, attracted to the negative electrode (cathode).
  • pH equal to pI: no net charge, it stays on the starting line.
  • pH above pI: the amino acid is an anion, attracted to the positive electrode (anode).

The further the pH is from the pI, the larger the average charge and the faster it moves; at the same charge, smaller ions move faster.

Aspartic acid (pI 3.0), glycine (pI 6.1) and lysine (pI 9.7) in a pH 6.0 buffer.

Interactive

Electrophoresis

Change the buffer pH and predict each amino acid's movement before you run it.

Glutamic acid (pI 3.2) and histidine (pI 7.6) are separated by electrophoresis in a buffer of pH 5.0. Which statement is correct?

Choose one answer

Worked example

Choose a buffer to separate two amino acids

  • Complex unfamiliar
  • Technology free

A mixture of glycine (pI 6.1) and lysine (pI 9.7) is spotted in the centre of an electrophoresis strip. (a) Predict the movement of each at pH 6.1. (b) Explain why a buffer of pH 3.0 would separate them less well than pH 6.1.

3 steps

Try it yourself first, then check the working one step at a time.

Method

  1. Compare the buffer pH with each pI.

  2. pH < pI → cation → negative electrode; pH > pI → anion → positive electrode; pH = pI → no movement.

  3. Choose a pH between the two pIs (or at one of them) for the clearest separation.

Watch out for

  • Saying an acidic buffer makes amino acids negative.

  • Assuming every amino acid has no charge at pH 7.

Exam tip

Analysing chromatograms and electrophoresis

Quote numbers: the RFR_F of each spot (two decimal places is plenty), the matching standard and its RFR_F. A substance is identified only if its RFR_F matches a standard's in the same solvent; two spots with similar RFR_F may need a second solvent to be sure. For electrophoresis, state the pH relative to each pI, the charge that gives, and the electrode it moves to.

Summary

  • Chromatography separates by competition: attraction to the polar stationary phase versus solubility in the mobile phase.

  • More attracted to the stationary phase: smaller RFR_F. More soluble in the solvent: larger RFR_F.

  • RFR_F = distance moved by the amino acid ÷ distance moved by the solvent, both from the baseline; no unit, between 0 and 1.

  • Amino acids are colourless: ninhydrin shows them as purple spots.

  • Electrophoresis: pH < pI cation → negative electrode; pH = pI no movement; pH > pI anion → positive electrode.

Finished the lesson?

Try the 2 quick checks above and the lesson completes itself, or mark it complete now.

Lesson 13 of 140% read

Save your progress with a free account