Lesson 6 of 7 · 20 min

Radioactive decay and Newton's law of cooling

Solve dNdt=−λN\frac{dN}{dt} = -\lambda N and dTdt=−k(T−Ts)\frac{dT}{dt} = -k(T - T_s) by separation of variables, find the constants from data, and use half-life and cooling models to answer questions in context.

What you will be able to do

  • Solve the decay equation dNdt=−λN\frac{dN}{dt} = -\lambda N and relate λ\lambda to the half-life.
  • Solve Newton's law of cooling dTdt=−k(T−Ts)\frac{dT}{dt} = -k(T - T_s) and find kk from a measurement.
  • Use the models to find times and values, with and without technology, and interpret them in context.

Two of the most useful differential equations say the same thing in different settings: the rate of change is proportional to the amount present (or to a difference).

In a radioactive sample, each nucleus has the same small chance of decaying each second, so the more nuclei there are, the faster they decay. A hot drink cools quickly when it is much hotter than the room and slowly once it is nearly at room temperature.

Interactive

Random decay, predictable curve

Each nucleus decays at random, but the number remaining halves every half-life, which is the exponential curve N=N0e−λtN = N_0e^{-\lambda t}.

Key idea

Exponential growth and decay

dNdt=kN  ⟹  N=N0ekt\frac{dN}{dt} = kN \quad\implies\quad N = N_0e^{kt}

where N0=N(0)N_0 = N(0). For radioactive decay, write k=−λk = -\lambda with decay constant λ>0\lambda > 0:

dNdt=−λN  ⟹  N=N0e−λt\frac{dN}{dt} = -\lambda N \quad\implies\quad N = N_0e^{-\lambda t}
Solving the decay equation

Separate: ∫1N dN=∫−λ dt\int \frac{1}{N}\,dN = \int -\lambda\,dt, so ln⁡(N)=−λt+c\ln(N) = -\lambda t + c (with N>0N > 0). Then N=ece−λt=Ae−λtN = e^{c}e^{-\lambda t} = Ae^{-\lambda t}. At t=0t = 0, N=AN = A, so A=N0A = N_0.

The half-life T1/2T_{1/2} is the time for NN to halve. Setting N=12N0N = \frac{1}{2}N_0:

12=e−λT1/2  ⟹  T1/2=ln⁡(2)λ\tfrac{1}{2} = e^{-\lambda T_{1/2}} \quad\implies\quad T_{1/2} = \frac{\ln(2)}{\lambda}

It does not depend on N0N_0: a sample of any size halves in the same time.

A radioactive isotope has a half-life of 88 days. Determine the exact value of its decay constant λ\lambda, in days⁻¹.

lambda =
Reads asYour answer shows here as maths.

Worked example

Radiocarbon dating a campfire

  • Complex familiar
  • Technology active

Carbon-14 decays according to dNdt=−λN\frac{dN}{dt} = -\lambda N and has a half-life of 57305730 years. Charcoal from an ancient campfire contains 30%30\% of the carbon-14 found in living wood. Estimate the age of the charcoal, to three significant figures.

5 steps

Try it yourself first, then check the working one step at a time.

Method

  1. Use N=N0e−λtN = N_0e^{-\lambda t} with λ=ln⁡(2)T1/2\lambda = \frac{\ln(2)}{T_{1/2}}.

  2. Write the remaining fraction as NN0\frac{N}{N_0} and solve with logarithms.

  3. Check against whole numbers of half-lives.

Watch out for

  • Using 0.70.7 instead of 0.30.3: 30%30\% remains, so NN0=0.3\frac{N}{N_0} = 0.3.

  • Treating "30 % remains" as "30 % of a half-life".

Newton's law of cooling says the rate at which an object's temperature TT changes is proportional to the difference between TT and the surrounding temperature TsT_s:

dTdt=−k(T−Ts),k>0\frac{dT}{dt} = -k(T - T_s), \quad k > 0

When T>TsT > T_s the right-hand side is negative, so the object cools. When T<TsT < T_s it is positive, so the object warms up. Either way it heads towards TsT_s.

Interactive

Cooling curves

The horizontal axis is time tt in minutes. The curve always levels off at the room temperature TsT_s; a larger kk means faster cooling. Try T0<TsT_0 < T_s for a cold drink warming up.

Key idea

Solving Newton's law of cooling

Separate, with T−Ts>0T - T_s > 0:

∫1T−Ts dT=∫−k dt  ⟹  ln⁡(T−Ts)=−kt+c\int \frac{1}{T - T_s}\,dT = \int -k\,dt \implies \ln(T - T_s) = -kt + c T=Ts+(T0−Ts)e−ktT = T_s + (T_0 - T_s)e^{-kt}

Two pieces of information fix the model: the starting temperature gives T0T_0, and one later reading gives kk.

Worked example

A cooling cup of tea

  • Complex familiar
  • Technology active

A cup of tea at 9090 °C is left in a room at 2020 °C. Its temperature TT °C after tt minutes satisfies dTdt=−k(T−20)\frac{dT}{dt} = -k(T - 20). After 1010 minutes the tea is at 6060 °C.

(a) Show that T=20+70e−ktT = 20 + 70e^{-kt}.

(b) Determine kk, exactly and to three significant figures.

(c) Determine when the tea reaches 4040 °C, to the nearest tenth of a minute.

5 steps

Try it yourself first, then check the working one step at a time.

Method

  1. Solve to T=Ts+(T0−Ts)e−ktT = T_s + (T_0 - T_s)e^{-kt}.

  2. Use the second reading and logarithms to find kk.

  3. Substitute the target temperature and solve for tt.

Watch out for

  • Writing T=90e−ktT = 90e^{-kt}, which cools towards 00 °C, not room temperature.

  • Rounding kk to 0.060.06 early, which gives t≈20.9t \approx 20.9 min.

A pie taken from a 200200 °C oven cools in a 2525 °C kitchen according to T=25+175e−0.05tT = 25 + 175e^{-0.05t}, where tt is in minutes. Determine the rate at which the pie is cooling when its temperature is 9595 °C, in °C per minute.

in circC min -1

Common mistake

Which temperature is which

TsT_s is the temperature of the surroundings, the value the object approaches. T0T_0 is the object's temperature at t=0t = 0. In T=Ts+(T0−Ts)e−ktT = T_s + (T_0 - T_s)e^{-kt}, check that t=0t = 0 gives T0T_0 and t→∞t \to \infty gives TsT_s.

Worked example

Estimating a time of death

  • Complex unfamiliar
  • Technology active

At 10:00 pm a forensic scientist measures the temperature of a body as 3030 °C. At 11:00 pm it is 2828 °C. The room is held at 2020 °C, and normal body temperature is 3737 °C.

Assuming Newton's law of cooling, dTdt=−k(T−20)\frac{dT}{dt} = -k(T - 20), estimate the time of death, and state one assumption that affects the estimate.

5 steps

Try it yourself first, then check the working one step at a time.

Method

  1. Put t=0t = 0 at the first measurement.

  2. Use the second measurement to find kk.

  3. Solve for the time when T=37T = 37 (negative tt is before the first reading).

  4. Convert to clock time and comment on assumptions.

Watch out for

  • Setting T(0)=37T(0) = 37 without knowing when t=0t = 0 is: the time of death is the unknown.

  • Reporting −2.378-2.378 h as "2 h 37 min": 0.3780.378 h is about 2323 minutes.

Without technology

Leave answers exact: k=110ln⁡(74)k = \frac{1}{10}\ln\left(\frac{7}{4}\right), t=ln⁡(2)λt = \frac{\ln(2)}{\lambda}. Use log laws to simplify.

With technology

Solve for kk or tt with the solve function or by graphing TT and the target value, and state the equation you solved. Round only the final answer.

Exam tip

Interpret your answer

State what the constant means ("the temperature difference falls by about 5.4%5.4\% each minute"), give times in sensible units (minutes, or hours and minutes), and comment on whether the model is reasonable. Newton's law assumes the room temperature stays constant.

Summary

  • dNdt=−λN\frac{dN}{dt} = -\lambda N gives N=N0e−λtN = N_0e^{-\lambda t}, with half-life T1/2=ln⁡(2)λT_{1/2} = \frac{\ln(2)}{\lambda}.

  • Newton's law of cooling, dTdt=−k(T−Ts)\frac{dT}{dt} = -k(T - T_s), gives T=Ts+(T0−Ts)e−ktT = T_s + (T_0 - T_s)e^{-kt}.

  • Find the constants from the initial value and one further measurement, using logarithms.

  • A rate at a given value can come straight from the differential equation.

  • Interpret results in context, with units, and judge whether the model holds.

Finished the lesson?

Try the 2 quick checks above and the lesson completes itself, or mark it complete now.

Lesson 6 of 70% read

Save your progress with a free account