Lesson 7 of 10 · 20 min

Investigating radiation and decay data

Correct count rates for background, estimate a half-life from an exponential decay graph, and analyse shielding and distance data from radiation experiments, judging the credibility of nuclear safety information.

What you will be able to do

  • Correct measured count rates for background radiation.
  • Estimate a half-life from an exponential decay graph using more than one pair of readings.
  • Analyse shielding data and the relationship between intensity and distance from a gamma source.
  • Evaluate the credibility of sources of information about nuclear safety.

In a school laboratory you can measure radiation with a Geiger–Müller (GM) tube and counter. The suggested investigations for this topic are shielding (how count rate changes with absorber thickness), distance (how count rate changes as you move away from a source) and half-life (from a decay graph). They all use the same three habits: measure the background, repeat counts, and analyse with a graph.

Note

Working safely

School sources are sealed and weak, but you still keep exposure as low as reasonably achievable: handle sources with tongs, point them away from people, keep them out of their lead-lined box only as long as needed, and wash your hands afterwards. The three controls are time (less of it), distance (more of it) and shielding.

Key idea

Correct for background first

A GM tube always detects background radiation from rocks, building materials, cosmic rays and even your body. Measure the background count rate with no source present, over a long time (several minutes) for a reliable average. Then

corrected count rate=measured count rate−background count rate\text{corrected count rate} = \text{measured count rate} - \text{background count rate}

Only the corrected count rate halves each half-life or follows the inverse square law.

A GM counter records 245 counts per minute near a source. The background count rate is 25 counts per minute. What will the counter record one half-life later?

in counts per minute

Half-life from a graph. Protactinium-234m has a half-life of about a minute, so you can watch it decay in one lesson. Plot the corrected count rate against time and draw a smooth curve of best fit through the points (not dot-to-dot). Because the decay is random, points scatter around the curve.

Corrected count rate for a protactinium-234m source. The dashed lines show two half-life readings: 80 → 40 and 40 → 20.

Worked example

Find a half-life from experimental data

  • Complex familiar
  • Technology free

A student records the count rate from a radioactive sample every 10 minutes. The background count rate is 20 counts per minute.

Measured count rates (counts per minute) at t=0,10,20,30,40,50,60t = 0, 10, 20, 30, 40, 50, 60 min: 500, 347, 242, 171, 123, 90, 68.

The corrected values are plotted below. Determine the half-life of the sample.

Corrected count rate against time, with a curve of best fit and two half-life readings.

5 steps

Try it yourself first, then check the working one step at a time.

Method

  1. Subtract background from every reading.

  2. Draw a smooth curve of best fit.

  3. Read the time for the curve to halve, at least twice, and average.

Watch out for

  • Halving the uncorrected values: 500 to 250 happens at about 19 min, giving a half-life that is too long.

  • Reading from individual points instead of the curve of best fit.

Interactive

Fit the decay curve

Change the half-life and the starting count rate. Whatever the starting value, the time to halve stays the same.

Using the decay graph above, the corrected count rate falls from 60 counts per second to 30 counts per second. Between which two times does this happen, approximately, and what half-life does it give?

Choose one answer

Shielding. Place absorbers of increasing thickness between the source and the GM tube and record the corrected count rate. For a beta source, aluminium a few millimetres thick brings the count rate down to background. For a gamma source, lead reduces the count rate in a curve that looks like a decay graph: each extra half-value thickness (about 1 cm of lead for cobalt-60 gamma rays) halves it.

Distance. Gamma rays from a small source spread out in all directions, so the same number of photons per second passes through bigger and bigger spheres. The intensity, and so the corrected count rate, follows an inverse square law: C∝1d2C \propto \dfrac{1}{d^2}. Doubling the distance quarters the count rate. (Alpha and beta are also absorbed by air, so they fall off faster than this.)

Interactive

Testing the inverse square law

Corrected count rate against 1d2\frac{1}{d^2} for a gamma source at distances from 10 cm to 40 cm. A straight line through the origin supports C∝1d2C \propto \frac{1}{d^2}.

At 20 cm from a small gamma source the corrected count rate is 48 counts per second. Predict the corrected count rate at 40 cm.

in counts s -1

Tip

Judging sources of nuclear safety information

Nuclear safety is an area full of strong opinions. When you research it, ask of each source:

  • Who wrote it, and what is their expertise? ARPANSA (the Australian Radiation Protection and Nuclear Safety Agency), ANSTO, the IAEA, the WHO and peer-reviewed journals are written by specialists and reviewed by others.
  • What evidence does it give? Look for data, measurements and references, not just claims.
  • Who benefits? Industry groups and campaign groups may present one side.
  • Is it current? Safety standards and reactor designs change.

Use several credible sources and say which you relied on and why.

Exam tip

Data analysis questions

Always say you subtracted background and show it. Read half-life from at least two pairs of points and average them. Draw the construction lines on the graph. When asked about errors, randomness of decay causes scatter (a random error, reduced by counting for longer), while not correcting for background is a systematic error.

Summary

  • Subtract background radiation from every measured count rate before you analyse it.

  • Estimate half-life from a smooth curve of best fit, using two or more halvings, and average.

  • Absorbers reduce the count rate: aluminium stops beta, lead reduces gamma by half for each half-value thickness.

  • For a small gamma source, corrected count rate ∝1d2\propto \frac{1}{d^2}, so doubling the distance quarters it.

  • Judge safety information by the author's expertise, the evidence given, possible bias and how current it is.

Finished the lesson?

Try the 3 quick checks above and the lesson completes itself, or mark it complete now.

Lesson 7 of 100% read

Save your progress with a free account