Lesson 4: Investigating enzyme activity
Rates from a catalase gas syringe experiment
SkillAnalysing enzyme experiments
Worked example
Catalase was added to hydrogen peroxide and the oxygen was collected in a gas syringe.
| Time (min) | 0 | 0.5 | 1.0 | 1.5 | 2.0 | 2.5 | 3.0 | 4.0 | 5.0 |
|---|---|---|---|---|---|---|---|---|---|
| Volume of O₂ (cm³) | 0 | 10 | 17 | 21 | 24 | 26 | 28 | 29 | 30 |
(a) Calculate the mean rate of oxygen production over the first 2.0 minutes. (b) Calculate the mean rate between 3.0 and 5.0 minutes. (c) Explain why the rate falls, and why the volume stops at 30 cm³.
Step 1: Mean rate over the first 2.0 minutes
Step 2: Mean rate from 3.0 to 5.0 minutes
Use the change in volume divided by the change in time over the interval asked for.
Step 3: Explain the fall in rate
As the reaction goes on, hydrogen peroxide is used up, so its concentration falls. Substrate molecules collide with active sites less often, fewer enzyme–substrate complexes form per minute, and the rate falls. The enzyme is not used up.
Step 4: Explain the final volume
At all the hydrogen peroxide has been broken down. The amount of product depends on the amount of substrate, so the volume can rise no further, even though the catalase is still active.
Answer
(a) 12 cm³ min⁻¹. (b) 1.0 cm³ min⁻¹. (c) The substrate is used up, so collisions with active sites become less frequent; the volume stops at 30 cm³ when all the H₂O₂ has reacted.
Try a similar one
A fresh question of the same kind, checked as you answer, with hints and a full solution.
Method
Rate = change in volume ÷ change in time over the interval.
A falling rate over time means the substrate is running out.
Watch out for
Saying the rate falls because the enzyme is used up or denatured.
Dividing the volume at 5 minutes by 5 for the rate between 3 and 5 minutes.