Lesson 11: Transformers and power transmission

Why the grid transmits at high voltage

SkillTransformers and power transmission

Worked example

  • Complex unfamiliar
  • Technology active

A power station sends 50 MW50\ \mathrm{MW} to a city through transmission lines with a total resistance of 4.0 Ω4.0\ \Omega. Compare the power lost in the lines when the power is transmitted at 25 kV25\ \mathrm{kV} and at 250 kV250\ \mathrm{kV}, and explain why the grid uses step-up transformers.

1 of 4 steps
  1. Step 1: Current at 25 kV

    I=PV=50×10625×103=2.0×103 AI = \dfrac{P}{V} = \dfrac{50 \times 10^{6}}{25 \times 10^{3}} = 2.0 \times 10^{3}\ \mathrm{A}

Try a similar one

A fresh question of the same kind, checked as you answer, with hints and a full solution.

Method

  1. Find the line current from I=PVI = \frac{P}{V} at each voltage.

  2. Find the loss from P=I2RP = I^2R.

  3. Compare, and link the comparison to transformers.

Watch out for

  • Using P=V2RP = \frac{V^2}{R} with the transmission voltage. The 25 kV25\ \mathrm{kV} is not across the line resistance; most of it is across the load.

Save your progress with a free account