Lesson 8: Flame tests and atomic absorption spectroscopy

Evaluating an AAS analysis of an iron-fortified drink

SkillAtomic absorption spectroscopy

Worked example

  • Complex unfamiliar
  • Technology active

An iron-fortified drink is labelled as containing 21.0 mg L−121.0\ \mathrm{mg\,L^{-1}} of iron. A student diluted 25.0 mL of it to 100.0 mL and measured the absorbance of the diluted solution three times: 0.224, 0.229 and 0.225. The calibration line for the iron standards passes through the origin with a gradient of 0.0451 L mg−10.0451\ \mathrm{L\,mg^{-1}}.

(a) Calculate the iron concentration of the drink.

(b) Determine the absolute and percentage uncertainty in the mean absorbance.

(c) Evaluate the label's claim.

1 of 6 steps
  1. Step 1: Mean absorbance

    Aˉ=0.224+0.229+0.2253=0.226\bar{A} = \dfrac{0.224 + 0.229 + 0.225}{3} = 0.226

Try a similar one

A fresh question of the same kind, checked as you answer, with hints and a full solution.

Method

  1. Average the replicates and find the uncertainty of the mean.

  2. Convert absorbance to concentration with the calibration line, then apply the dilution factor.

  3. Compare the percentage error with the percentage uncertainty to judge the claim, and name likely sources of error.

Watch out for

  • Forgetting the dilution factor and reporting 5.01 mg/L.

  • "Human error" as the only explanation. Name a specific source and say which way it would push the result.