Lesson 5: Calculating magnetic fields: wires and solenoids
The superconducting magnet in an MRI scanner
SkillFields of wires and solenoids
Worked example
An MRI scanner's main magnet is a long solenoid wound with turns per metre.
(a) Calculate the current needed to make a field inside it.
(b) If the same coil were made of ordinary copper wire with a total resistance of , calculate the power it would dissipate.
(c) Explain why MRI magnets are wound with superconducting wire.
Step 1: Rearrange the solenoid formula
Step 2: Find the current
, or to two significant figures.
Step 3: Find the power in a copper coil
is the heating in a resistor from Unit 1. With hundreds of amperes, even a small resistance turns a lot of energy into heat.
Step 4: Explain the superconductor
Cooled in liquid helium to about , below its critical temperature, the niobium–titanium wire has zero resistance. The current then flows with no heating, so no power is wasted in the wire and the current keeps circulating without a power supply. A copper coil would need about around the clock and would overheat.
Answer
(a) (b) (c) Zero resistance means no heating, so a very large current can flow continuously without wasting energy.
Try a similar one
A fresh question of the same kind, checked as you answer, with hints and a full solution.
Method
Rearrange for the unknown.
Use to judge the heating a large current would cause.
Link zero resistance to zero heating in the explanation.
Watch out for
Using the total number of turns instead of turns per metre.