Lesson 9: Transpiration and its rate

Calculate a transpiration rate from potometer readings

SkillTranspiration experiments

Worked example

  • Complex familiar
  • Technology active

A bubble potometer has a capillary tube of internal diameter 1.0 mm1.0\unit{mm}. In three 5-minute trials with the same leafy shoot, the bubble moved 4242, 4545 and 39 mm39\unit{mm}. The shoot's total leaf area was 48 cm248\unit{cm^2}.

(a) Calculate the mean distance moved. (b) Calculate the mean rate of water uptake in mm3 min−1\mathrm{mm^3\,min^{-1}}, with its uncertainty. (c) Calculate the rate per cm2\mathrm{cm^2} of leaf, and explain why this is useful.

1 of 5 steps
  1. Step 1: Mean distance

    42+45+393=42 mm\dfrac{42 + 45 + 39}{3} = 42\unit{mm}

Try a similar one

A fresh question of the same kind, checked as you answer, with hints and a full solution.

Method

  1. Average the distances, then V = πr²d with the radius.

  2. Rate = V ÷ t. Uncertainty = half the range, as a percentage.

  3. Divide by leaf area to compare plants.

Watch out for

  • Using the diameter as rr.

  • Giving the rate as distance per minute when a volume rate is asked for.

Save your progress with a free account